Sign In | Join Free | My tjskl.org.cn
China DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD logo
DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
Dongguan Daxian Instrument Equipment Co.,Ltd. CHINA'S LEADER IN TESTING EQUIPMENT Professional Manufacturer of Building Materials 13 years Fire Retardant / Wire/ Plastics/ Rubber/ Environmental
Verified Supplier

6 Years

Home > Construction Materials Testing Equipment >

5% Accuracy Thermal Insulation Conductivity Testing Equipment ISO/DIS830 AC 220V 50HZ

DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

5% Accuracy Thermal Insulation Conductivity Testing Equipment ISO/DIS830 AC 220V 50HZ

  • 1
  • 2

Brand Name : DAXIAN

Model Number : DX8377

Certification : GB/T10295-2008、ISO/DIS8301

Place of Origin : China

MOQ : 1 set

Price : Negotiable

Packaging Details : Standard export wooden case

Delivery Time : 30 days after order confirmed

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash

Supply Ability : 30 sets per month

Name : ISO/DIS8301 Thermal insulation- steady- state thermal resistance and related properties- heat flow meter apparatus

Accuracy : 5%

Power supply : AC 220V; 50HZ

The test range : 0.1 ~ 300w/m • k

Heat flow range : 0.5-2000W/m2

Sample size : Φ130 × (1-100) mm

The timing part range : 0 ~ 999.9s; resolution 0.1s;

Warranty : 12 months

Contact Now

Construction Materials Fire Resistance Thermal Conductivity Testing Equipment

Scope of application:

Thermal conductivity of dry test pieces of clay and sand, the thermal resistance of the sample should be greater than 0.1m2.K / W.

A thermal flow meter is used to detect the thermal conductivity and thermal resistance of clay, sand, etc., and the computer is used to realize automatic detection and generate an experimental report. The instrument adopts a stable hot surface temperature on the side of the sample, and the heat is transferred to the cold surface (room temperature) through the sample, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance. Specially equipped with geotechnical sample cylinder and specific heat capacity test device, which can be used for thermal conductivity analysis and specific heat capacity determination of clay, sand and other soils.

Standard:

It conforms to GB / T10295-2008 "Determination of Steady State Thermal Resistance and Related Characteristics of Thermal Insulation Materials" and ISO / DIS8301 "Insulation-Determination of Steady State Thermal Resistance and Related Characteristics-Heat Flow Meter Device".

Technical parameters:

1. Thermal conductivity range:

Plate-like sample 0.015-400W/mk, accuracy better than 5%; Cylindrical sample 3-400W/mk, accuracy less than 5%;

(A round sample cylinder with rock-finish soil, Ф90mm)

2. Hot surface temperature: room temperature -99.99 °C, the use of high digital display meter temperature measurement, 0.2 precision, resolution 0.01 °C.

3. Cold surface temperature: room temperature, using a high digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C.

4. Hot surface temperature control: room temperature -99.99 °C, using a high number of digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C, flat heater, two-way SCR control.

5. Cold forced air cooling. The cold side is water-cooled to ensure stable cold face temperature (optional for temperature users)

6. Using computer automatic testing.

7. Heat flow range: 0.5-2000W/m2, delivery rate of 0.25 W/m2.

8. Using WPY heat flow meter, heat flow parameters 23.26w/m2.mV.

9. Using plexiglass windshield, can directly observe the experimental process.

10. Uot and cold plate heat transfer area: 150 × 150 (mm), (can be manufactured according to user requirements 300/300,600/600 and other specifications of the sample).

11. Adjustable hot and cold plate spacing: 0-160 (mm).

The main technical parameters:

The test range 0.1 ~ 300w/m • k
Power supply AC 220V; 50HZ
Heat source heating copper block, using 36V safe voltage heating.
Test materials block or cylindrical metal, non-metallic materials, can test powder, gelatinous and other samples;
Measuring temperature range room temperature ~ 250 °C, up to 550 °C, accuracy ± 1 °C;
The timing part range 0 ~ 999.9s; resolution 0.1s;
Thermal conductivity measurement accuracy better than 10%
Sample size Φ130 × (1-100) mm

5% Accuracy Thermal Insulation Conductivity Testing Equipment ISO/DIS830 AC 220V 50HZ


Product Tags:

thermal conductivity testing equipment

      

calorific value testing machine

      
Quality 5% Accuracy Thermal Insulation Conductivity Testing Equipment ISO/DIS830 AC 220V 50HZ for sale

5% Accuracy Thermal Insulation Conductivity Testing Equipment ISO/DIS830 AC 220V 50HZ Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)